Input
Range
Resolution
Accuracy
Sensor type
Sensor Cable Length
Display
L.E.D. Indication
Set Point
Hysterisis
Control Action
Time Delay
Relay Contact Type
Configuration Of Relay
Fault Condition
Setting
Monitoring Sensor
Retransmission Output
Communication
Supply Voltage
Operating Temperature
Relative Humidity
Sensor Housing
Enclosure Detail
Protection Class
Cabinet Material
Cable Entry
Dimension
Cutout
Mounting
Weight |
Temperature Humidity
- 40 To 120 0C 0 To 100 % RH
0.10C 0.1% RH
± 0.3 % of Full Scale ± 1.8 % of Full Scale
i) Band gap temperature sensor for Temperature ii) Capacitive polymer sensing for Relative Humidity
Standard 1 meter, can extend upto 15 m on requrest
Upper : 4 Digit, 0.56” (13 mm), 7 segment RED L.E.D display for Humidity
Lower : 4 Digit, 0.56” (13 mm), 7 segment RED L.E.D display for Temperature
TD1 & TD2 for Time Delay, RL1 & RL2 for Relays, TX & RX for Communication,
PRG to show ‘User’ in Programming mode, DEW to show Lower display shows ‘Dew point’
Two independent set points, one each for RL1 & RL2 with programmable Latch & Non-Latch facility
0 To 10, Independent setting for RL1 & RL2
LO - HI, HI - LO, LO - Very LO, HI - Very HI; programmable by user
0 To 9999 sec, Independent setting for RL1 & RL2 to operate after the ‘Process Value’ crosses ‘Set point Value’
1 NO - C - NC Relay contact Rated 230 VAC/5A for RL1 & RL2
RL1 operates for Humidity, RL2 operates for Temperature
In ‘Under’, ‘Over’ OR ‘Open’ condition i.e. fault condition, Relay can be made OFF or ON; programmable by user
Setting by 4 keys on front panel i.e. ‘SET / NEXT’, ‘UP’, ‘DOWN’ & ‘ DEW / BACK’
NOTE : If you press ‘ DEW / BACK’ key, Lower Display shows ‘Dew Point’
i) By Display : Sensor ‘Break / Open’ shows ‘oPEn’ Indication
ii) By Retransmission current O/Ps : Up scale current : 21 mA, Down scale current : 3 mA; programmable by user
i) 2 No, 4 - 20 mA OR 20 - 4 mA programmable with max load 750 ohms for Temp & Humidity
ii) Range: - 999 To 9999, Low range & High range : Anywhere in the range (High range > Low range)
Modbus RTU protocol with Isolated RS-485 communication
230 VAC ± 10 % OR 110 VAC ± 10 % OR 24 VDC
- 40 To 85 0C
Below 95% non condensing
P.V.C. / SS316, Please specify while ordering
PANEL MOUNTING (PM) WEATHERPROOF (WP) FLAMEPROOF (FLP)
IP - 40 IP- 65 IP-65, CMRI Approved for IIA & IIB Gas Group
ABS Plastic, White Colour Polycarbonate Colour Grey Cast Alluminium Alloy, LM-6,/C.I. Enclosure
Terminal connector for connection Thermoplastic cable gland (IP-68) Double compression cable gland (Ex-Proof)¾” ET-type
96 (H) X 96 (W) X 120 (D) in mm 215(H) X 240(W) X 120(D) in mm 300(H) X 250(W) X 110(D) in mm
92(H) x 92(W) in mm - - - - - - - - - - - -
Panel mounting Wall Mounting / Stand Mounting Wall Mounting / Stand Mounting
Approx 1.0 Kg Approx. 2.5 Kg Approx. 4.0 Kg |